Application note ·
Battery module CT segmentation: Royma Laboratory CT labels every component

Royma Laboratory CT scans a complete battery module and separates the 3D volume into individually labelled components – cells, busbars, cooling channels, fasteners and housings – so that the position and alignment of every part can be shown and measured. This battery module CT segmentation gives failure-analysis and validation engineers the whole assembly as a set of named parts, before anyone opens the housing.
The segmented volume covers the module and the cells inside it:
- Cells, busbars, tabs and terminals as separate objects, each with its position and alignment
- Cooling channels, fasteners and housings, each labelled and measurable
- Rivets, centre pins, current interrupt devices (CIDs), PTC ceramics, shortcut c-tabs and plastic protection plates inside the assembled cells
- Misplaced screws and connectors, discontinuities at tabs, busbars and joints, structural misalignment, and pinched or misrouted cabling
Once a module is sealed, an assembly error is invisible from the outside. A teardown can find it, but releasing fasteners and lifting covers also moves the parts that are under investigation.
One scan, every part labelled
Royma Laboratory CT records the assembled module in a single computed tomography (CT) volume. Royma’s segmentation software then separates that volume into individually labelled objects: cells, busbars, cooling channels, fasteners, housings and the other parts of the assembly. Each object can be shown on its own, hidden, coloured or measured against its neighbours. The engineer works with the module as a set of named parts in their as-built positions rather than as one grey block.
Because the separation is digital, the physical module stays intact. The same object can be viewed in a slice, in a 3D rendering or as a single extracted part. The scan can be repeated after a test, and the two volumes can be compared part by part.
“With a segmented CT volume, the failure analysis starts from the module exactly as it was built,” says Gabor Szabo, Sales Director Europe, Royma Europe. “Every cell, busbar and fastener is a labelled object, so our customers check position and alignment part by part and keep the module for the next test.”
Connections and fasteners checked in place
Busbars, tabs and terminals carry the current of the module, and a discontinuity at one joint affects the whole string. In the segmented volume each busbar and tab is a separate object, so its seat against the cell terminal and its alignment with the neighbouring parts are shown directly. Discontinuities at tabs, busbars and joints appear where they are, in their as-built state.
Fasteners and connectors are labelled in the same way. A screw in the wrong position, a missing connector or a connector seated at an angle stands out against the expected layout of the module. Cabling inside the housing is separated from the surrounding parts, so a pinched or misrouted cable can be followed along its full path.
Cooling channels and housings complete the picture. Royma Laboratory CT shows whether the cooling channels sit where the design places them and whether the housing and the cell stack are aligned with each other. Structural misalignment that would only show up at teardown is visible in the CT data of the closed module.
Safety parts verified inside the cells
The CT inspection does not stop at the module level. Inside each fully assembled cell, Royma Laboratory CT confirms the geometry and position of rivets, centre pins, CIDs, PTC ceramics, shortcut c-tabs and plastic protection plates. These parts govern controlled venting, disconnection and electrical safety, and incorrect placement cannot be seen from outside a sealed cell.
The check works both after assembly and after testing. A module scanned before and after a test shows whether a safety part has shifted, deformed or developed an internal defect, without opening the cell. Failure analysis thus starts from evidence that the investigation itself has not changed.
| Component | What the segmented CT volume shows |
|---|---|
| Cells | Position and alignment within the module |
| Busbars, tabs and terminals | Position, alignment and discontinuities at joints |
| Fasteners and connectors | Misplaced screws and connectors |
| Cabling | Pinched or misrouted cables |
| Cooling channels and housings | Structural misalignment |
| Rivets, centre pins, CIDs, PTC ceramics, shortcut c-tabs, plastic protection plates | Geometry and position after assembly and after testing; misalignment, deformation and internal defects |
Resolution, scan time and the level of detail of the segmentation depend on the size and materials of the module and are agreed per application after a test scan. The method suits modules and packs in batteries and automotive applications alike.
“The segmented scan replaces guesswork about what moved during a teardown,” says Gabor Szabo. “Our customers see each part where it was built and decide from that which part to open, if any.”
CT segmentation thus turns a sealed module into a part-by-part record of its assembly and a starting point for root-cause analysis.
Test scans available
Royma offers test scans of battery modules and cells through its inspection services. Send a module or describe your inspection task, and we return a segmented CT volume of your part.
Contact Gabor Szabo, Sales Director Europe, Royma Europe, gabor_szabo@roymatek.eu, +49 15156503316 – www.roymatek.eu.
About Royma: Royma Industrial CT develops and builds industrial X-ray and computed tomography systems, from 2D X-ray to horizontal, gantry, planar and inline CT. Royma Europe, Hannover, Germany – www.roymatek.eu.